tempstar furnace codes

If you’re looking for help fixing your Tempstar furnace, look no further! Our comprehensive Tempstar furnace repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.

CODE: Heartbeat LED pattern on solid
PROBLEM: The control is locked out and will auto-reset after 1 hour.
FIX: Reset power to clear the lockout.

CODE: Two LED flashes
PROBLEM: Pressure switch didn’t open.
FIX: Obstructed pressure tubing; a pressure switch that’s stuck closed.

CODE: Three LED flashes
PROBLEM: The low-pressure switch did not close or has reopened.
FIX: Proper vent sizing; air leak; restricted vent; clogged condensate drain; low input gas pressure; excessive wind; improper pressure switch wiring; water in vent piping; disconnected or obstructed pressure tubing.

CODE: Four LED flashes
PROBLEM: Limit circuit fault.
FIX: Loose blower wheel; defective switch or connections; improper minimum- or maximum-heat gas input adjustment; dirty filter or restricted duct system; improper limit switch.

CODE: Five LED flashes
PROBLEM: Abnormal flame-proving signal.
FIX: Leaky gas valve; stuck-open gas valve.

CODE: Six LED flashes
PROBLEM: Ignition proving a failure.
FIX: Low inlet gas pressure; control ground continuity; gas valve defect; defective hot surface igniter; oxide buildup on the flame sensor; inadequate flame carryover; flame sensor mustn’t be grounded.

CODE: Seven LED flashes
PROBLEM: Limit circuit lockout.
FIX: Control will auto-reset after 3 hours. Refer to status code #4.

CODE: Eight LED flashes
PROBLEM: Gas heating lockout.
FIX: Gas valve stuck closed on control.

CODE: Nine LED flashes
PROBLEM: Medium pressure switch, high-pressure switch, or PSR relay didn’t close or was reopened.
FIX: Refer to status code #3.

CODE: Ten LED flashes
PROBLEM: Polarity.
FIX: Correct line voltage polarity.

CODE: Status codes 1 + 2
PROBLEM: Blower on after power-up.
FIX: Normal operation.

CODE: Status codes 1 + 5
PROBLEM: Blower motor lockout.
FIX: Control will auto-reset after 3 hours. Refer to status code #4 + 1.

CODE: Status codes 3 + 5
PROBLEM: Gas valve fault.
FIX: RED, YELLOW, or ORANGE wire at the gas valve.

CODE: Status codes 4 + 1
PROBLEM: Blower motor fault.
FIX: Blower failed to reach 250 RPM, or the blower failed to communicate within the prescribed time limits.

CODE: Status codes 4 + 2
PROBLEM: Inducer motor fault.
FIX: Proper vent sizing; restricted vent; failed inducer motor; improper motor wiring; a blockage in the tubing to the pressure switch assembly.

CODE: Status codes 4 + 3
PROBLEM: The low or medium pressure switch is open while the medium or high-pressure switch is closed.
FIX: Low inlet gas pressure; clogged condensate drain; improper pressure switch wiring; water in vent piping; low or medium pressure switch stuck open; disconnected or obstructed pressure tubing.

CODE: Status codes 6 + 1
PROBLEM: Ignition lockout.
FIX: Control will auto-reset after 3 hours. Refer to status code #6.

tempstar furnace codes

 


What Our Clients Are Saying About Us

I would recommend KDM for sure

Colin JacobsCourtice, ON

I would recommend KDM for any of the services they provide

Douglas PattersonWhitby, Ontario

KDM was hired for the Installation and relocation of internal gas line

Paul AlisonOshawa, Ontario

Daniel and Steve were amazing, very professional work and courteous

Rajshar MahomesMarkham, Ontario

I would not hesitate to hire Daniel and his crew again

Ian DavidPickering, Ontario

I definitely recommend KDM Home & gas for others

RajeevAjax, Ontario

Everything was quick and efficient

Chris SouthamWhitby, Ontario

He is reliable and pleasant

IreneWhitby, ON

Dan and Steve from KDM did a great job.

RichardAjax, ON

Excellent customer service. Reliable and on time for appointments or called promptly to reschedule.

PaulcathPickering, ON