mrcool furnace codes

If you’re looking for help fixing your MrCool furnace, look no further! Our comprehensive MrCool furnace repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.

CODE: E1.
PROBLEM: Actuation of high pressure switch.
FIX: Abnormality is detected when the contact of the high pressure switch opens for 3 sec. The system will be shut down. The unit will report this fault. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.

CODE: E3.
PROBLEM: Actuation of low pressure switch.
FIX: When the unit runs more than 4 minutes or does not run, the low pressure switch opens for more than 3sec and the system will be shut down. The unit will report this fault. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.

CODE: E4.
PROBLEM: Air discharge high temperature protection of compressor.
FIX: The exhaust temperature is higher than 125C for more than 5sec, the system will be shut down. After stopping the compressor for 3 mins, if the exhaust temperature is lower than 90C for more than 5 sec, the compressor will re-start. For the first two faults within 30 minutes, the unit can be recovered automatically. If over three times, the unit cannot be recovered automatically.

CODE: F2.
PROBLEM: Malfunction of condenser temperature thermistor.
FIX: Malfunction of condenser temperature thermistor is detected when there is a short circuit or an open circuit in the condenser temperature thermistor for more than 5 sec. The system will be shut down. The reset for the malfunction of condenser temperature thermistor is automatic.

CODE: F3.
PROBLEM: Malfunction of outdoor ambient temperature thermistor.
FIX: Malfunction outdoor ambient temperature thermistor is detected when there is a short circuit or an open circuit in the outdoor ambient temperature thermistor for more than 5 sec. The system will be shut down. The reset for the malfunction of condenser temperature thermistor is automatic.

CODE: F4.
PROBLEM: Malfunction of Exhaust Temp. Sensor.
FIX: If the exhaust temperature sensor is detected of open circuit 5 seconds successively after the compressor is started for 2 minutes or short circuit 5 seconds successively at any time . The system will be shut down. After the fault is eliminated, the system can automatically resume to operation.

CODE: ON.
PROBLEM: Normal operation.
FIX: Unit operating normally or in standby mode.

mrcool furnace codes

 


What Our Clients Are Saying About Us

I would recommend KDM for sure

Colin JacobsCourtice, ON

I would recommend KDM for any of the services they provide

Douglas PattersonWhitby, Ontario

KDM was hired for the Installation and relocation of internal gas line

Paul AlisonOshawa, Ontario

Daniel and Steve were amazing, very professional work and courteous

Rajshar MahomesMarkham, Ontario

I would not hesitate to hire Daniel and his crew again

Ian DavidPickering, Ontario

I definitely recommend KDM Home & gas for others

RajeevAjax, Ontario

Everything was quick and efficient

Chris SouthamWhitby, Ontario

He is reliable and pleasant

IreneWhitby, ON

Dan and Steve from KDM did a great job.

RichardAjax, ON

Excellent customer service. Reliable and on time for appointments or called promptly to reschedule.

PaulcathPickering, ON