ducane air conditioner codes

If you’re looking for help fixing your Ducane air conditioner, look no further! Our comprehensive Ducane air conditioner repair guide will explain common issues, provide troubleshooting tips, and show you how to read your model’s error codes.

CODE: POWER (Green).
PROBLEM: Module has power
FIX: Supply voltage is present at module terminals.

CODE: TRIP (Red).
PROBLEM: Thermostat demand signal Y1 is present, but the compressor is not running
FIX: 1. Compressor protector is open – Check for high head pressure – Check compressor supply voltage 2. Outdoor unit power disconnect is open 3. Compressor circuit breaker or fuse(s) is open 4. Broken wire or connector is not making contact 5. Low pressure switch open if present in system 6. Compressor contactor has failed open.

CODE: ALERT (Yellow) Flash Code 1.
PROBLEM: Long Run Time Compressor is running extremely long run cycles

CODE: ALERT (Yellow) Flash Code 2.
PROBLEM: System Pressure Trip Discharge or suction pressure out of limits or compressor overloaded
FIX: 1. High head pressure – Check high pressure switch if present in system – Check if system is overcharged with refrigerant – Check for non-condensable in system 2. Condenser coil poor air circulation (dirty, blocked, damaged) 3. Condenser fan is not running – Check fan capacitor – Check fan wiring and connectors – Check fan motor for failure or blockage 4. Return air duct has substantial leakage 5. If low pressure switch present in system, check Flash Code 1 information.

CODE: ALERT (Yellow) Flash Code 3.
PROBLEM: Short Cycling Compressor is running only briefly
FIX: 1. Thermostat demand signal is intermittent 2. Time delay relay or control board defective 3. If high pressure switch present, go to Flash Code 2 information 4. If low pressure switch present, go to Flash Code 1 information.

CODE: ALERT (Yellow) Flash Code 4.
PROBLEM: Locked Rotor
FIX: 1. Run capacitor has failed 2. Low line voltage (contact utility if voltage at disconnect is low) – Check wiring connections 3. Excessive liquid refrigerant in compressor 4. Compressor bearing are seized 5. Measure compressor oil level.

CODE: ALERT (Yellow) Flash Code 5.
PROBLEM: Open Circuit
FIX: 1. Outdoor unit power disconnect is open 2. Compressor circuit breaker or fuse(s) is open 3. Compressor contactor has failed open – Check compressor contactor wiring and connectors – Check for compressor contactor failure (burned, pitted, or open) – Check wiring and connectors between supply and compressor – Check for low pilot voltage at compressor contactor coil 4. High pressure switch is open and requires manual reset 5. Open circuit in compressor supply wiring or connections 6. Unusually long compressor protector reset time due to extreme ambient temperature 7. Compressor windings are damaged – Check compressor motor winding resistance.

CODE: ALERT (Yellow) Flash Code 6.
PROBLEM: Open Start Circuit. Current only in run circuit
FIX: 1. Run capacitor has failed 2. Open circuit in compressor start wiring or connections – Check wiring and connectors between supply and the compressor S terminal 3. Compressor start winding is damaged – Check compressor motor winding resistance.

CODE: ALERT (Yellow) Flash Code 7.
PROBLEM: Open Run Circuit. Current only in start circuit.
FIX: 1. Open circuit in compressor run wiring or connections – Check wiring and connectors between supply and the compressor R terminal 2. Compressor run winding is damaged – Check compressor motor winding resistance.

CODE: ALERT (Yellow) Flash Code 8.
PROBLEM: Welded Contactor. Compressor always runs
FIX: 1. Compressor contactor has failed closed 2. Thermostat demand signal not connected to module.

CODE: ALERT (Yellow) Flash Code 9.
PROBLEM: Low Voltage. Control circuit less than 17VAC
FIX: 1. Control circuit transformer is overloaded 2. Low line voltage (contact utility if voltage at disconnect is low) – Check wiring conditions.

ducane air conditioner codes

 


What Our Clients Are Saying About Us

Excellent customer service!

TammiWhitby, ON

Very pleasant and gave me full instructions on operation

IreneWhitby, ON

My experience with KDM was spectacular from start to finish.

DwayneToronto, ON

We were very pleased with the work that KDM recently completed for us.

rbm0447Oshawa, ON

Dan and his team were efficient, honest, and easy to deal with

JoeToronto, ON

Amazing service! Great guys, very nice and helpful.

ChauntelleAjax, ON

On the ball, he was organized and efficient.

SteveToronto, ON

Great work with amazing service, the work was done efficiently and precisely.

arachnomme68Courtice, ON

Kdm was professional, knowledgeable, fair priced and very friendly.

Private UserBowmanville, ON

He is courteous, professional, he takes pride in his work.

Randy Whitby, ON