Code: 16
Problem: System Communications Failure
Fix: Communication with User Interface lost. Check wiring to UI, indoor and outdoor units

Code: 25
Problem: Invalid Model Plug
Fix: Control does not detect a model plug or detects an invalid model plug. Unit will not operate without correct model plug

Code: 31
Problem: High Pressure Switch Open
Fix: High – pressure switch trip. Check refrigerant charge, outdoor fan operating and coils for airflow restrictions

Code: 32
Problem: Low Pressure Switch Open
Fix: Low – pressure switch trip. Check refrigerant charge and indoor air flow.

Code: 45
Problem: Control Fault
Fix: Outdoor unit control board has failed. Control board needs to be replaced.

Code: 46
Problem: Brown Out (230v)
Fix: Line voltage < 187v for at least 4 seconds.

Code: 47
Problem: No 230v at Unit Measured at L1 and L2 on circuit board
Fix: There is no 230v at the contactor when indoor unit is powered and cooling/heating demand exists.

Code: 53
Problem: Outdoor Air Temp Sensor Fault
Fix: Outdoor air sensor not reading or out of range.

Code: 55
Problem: Outdoor Coil Sensor Fault
Fix: Coil sensor not reading or out of range. Ohm out sensor and check wiring.

Code: 56
Problem: Thermistors out of range
Fix: Improper relationship between coil sensor and outdoor air sensor. Ohm out sensor and check wiring.

Code: 71
Problem: Low Stage Thermal Cut out
Fix: Compressor operation detected then disappears while low stage demand exists. Possible causes are internal compressor overload trip or start relay and capacitor held in circuit too long

Code: 72
Problem: High Stage Thermal Cut out
Fix: Compressor operation detected then disappears while low stage demand exists. Possible causes are internal compressor overload trip or start relay and capacitor held in circuit too long

Code: 73
Problem: Contactor Shorted
Fix: Compressor voltage sensed when no demand for compressor operation exists. Contactor may be stuck closed or there is a wiring error

Code: 74
Problem: No 230v at Compressor
Fix: Compressor voltage not sensed when compressor should be starting. Contactor may be stuck open or there is a wiring error

Code: 75
Problem: Low Stage Did Not Start
Fix: Specified start voltage at VR terminal was not achieved in low stage. Start relay was de-energized after 1 second

Code: 76
Problem: Low Stage Did Not Start 3 times
Fix: For 3 consecutive low stage starts, the specified start voltage at VR terminal was not achieved and start relay was de-energized. Low stage locked out for 30 minutes.

Code: 77
Problem: High Stage Did Not Start
Fix: Specified start voltage at VS terminal was not achieved in high stage. Start relay was de-energized after 1 second

Code: 78
Problem: High Stage Did Not Start 3 times
Fix: For 3 consecutive high stage starts, the specified start voltage at VS terminal was not achieved and start relay was de-energized. High stage locked out for 30 minutes

Code: 81
Problem: Low Stage Thermal Lockout
Fix: Thermal cutout occurs in three consecutive low/high stage cycles. Low stage locked out 4 hours or until 24v power recycled

Code: 82
Problem: High Stage Thermal Lockout

bryant air conditioner codes

 


What Our Clients Are Saying About Us

I would recommend KDM for sure

June 26, 2020

Dan was very friendly and polite from the start. Did exactly the work that we talked about on the phone, and was very quick making a late evening call on a Sunday. Tested all the joints and even painted the gas lines. I would recommend him for sure.

Colin JacobsCourtice, ON

I would recommend KDM for any of the services they provide

June 26, 2020

I had a 2nd hand pool heater hooked up and needed help getting it fired up. So I contacted Dan at KDM to see if they could help and was pleased he could make it over within a couple of days. He checked out the gas piping for leaks and proceeded to analyze the components of the control system and determined a faulty pressure switch was likely preventing operation. I was able to source the part and Dan was able to make a 2nd call within a day to install and complete the job. So in summary, I would recommend KDM for any of the services they provide.

Douglas PattersonWhitby, Ontario

KDM was hired for the Installation and relocation of internal gas line

June 26, 2020

KDM was hired for the Installation and relocation of internal gas line for my basement finishing project.

Paul AlisonOshawa, Ontario

Daniel and Steve were amazing, very professional work and courteous

June 26, 2020

Daniel and Steve were amazing, very professional work and courteous….never dealt with more friendly and knowledgeable Hvac technicians.

Rajshar MahomesMarkham, Ontario

I would not hesitate to hire Daniel and his crew again

June 26, 2020

Asked for quotes on a A/C and furnace after 17 years when the A/C unit broke down. I contacted a few HVAC contractors including KDM. Daniel could not have been more helpful and responsive and after reviewing the quotes decided to hire him for the job. Could no have made a better choice. Daniel was patient and upfront and answered all my questions when asked. He upgraded my A/C unit for the same price after the original unit we agreed upon was back ordered. The crew came when they said they would an completed the installation in a timely and orderly fashion.

I would not hesitate to hire Daniel and his crew again. In fact he is coming back to deal with another issue I have next month!

Job well done.

Ian DavidPickering, Ontario

I definitely recommend KDM Home & gas for others

June 26, 2020

I was looking for someone who can do the gas line connection on a weekend and I found the right guys with KDM Home & Gas. Daniel came on Sunday morning to do the work. He installed the new gas line, connected the new gas stove, confirmed no leaks and ensured everything works fine. It was a really hot day outside but he did an excellent job.

.

RajeevAjax, Ontario

Everything was quick and efficient

June 26, 2020

Assessment happened on a holiday and work was completed the following day. Everything was quick and efficient.
Thanks Daniel.

Chris SouthamWhitby, Ontario