CODE: FP.
PROBLEM: Freeze Protection Engaged. The room temperature measured by the wireless remote thermostat or indoor ambient thermistor active sensor falls below 40°F.
FIX: No Action required. This setting will disengage when the room temperature rises above 43°F.

CODE: Fd.
PROBLEM: Front Desk switch is closed. All outputs are switched off.
FIX: Open front desk switch to allow occupant unit operation.

CODE: Eo.
PROBLEM: Un-Configured Service Board – All operation held awaiting configuration.
FIX: Enter Configuration Menu and set “C3” to “C” for coolers with electric heat or “H” for heat pumps.

CODE: EH.
PROBLEM: Emergency Hydronic Engaged. The EHH switch is closed. Compressor is switched off.
FIX: Open front emergency hydronic switch to allow occupant unit operation.

CODE: LS.
PROBLEM: Load Shedding Engaged. The LS switch is closed. Compressor and Electric heat is switched off.
FIX: Open load shedding switch to allow occupant unit operation.

CODE: On.
PROBLEM: Control is configured to respond to a wired thermostat.
FIX: No action if a wired thermostat is being used.Otherwise, see Configuration Settings.

CODE: oP.
PROBLEM: Open Door Lockout (DS1 & DS2 open; wireless).
FIX: Close Room Door. Unit will not condition space with door open.

CODE: nP.
PROBLEM: Window Switch Lockout – (LS & INN open).
FIX: Close Room Door or Window. Unit will not condition space with door or window open.

CODE: HP.
PROBLEM: Heat Sentinel – (WIAT > u3).
FIX: No action required. This setting will disengage when the room temperature falls.

CODE: Ur.
PROBLEM: Un-Rented Status (EHH & INN or wireless).
FIX: Front Desk needs to set to Rented mode (if applicable).

CODE: F1.
PROBLEM: Indoor Ambient Thermistor reads outside the range -20°F to 200°F & the wireless thermostat is not communicating to the unit control or Indoor Ambient Thermistor (IAT) without a wireless remote thermostat reads outside the range -20°F to 200°F.
FIX: Replace black Indoor Ambient Thermistor or Wireless Remote Thermostat.

CODE: F2.
PROBLEM: Wireless Remote Thermostat failure.
FIX: Replace Wireless Thermostat.

CODE: F3.
PROBLEM: Indoor Ambient Thermistor reads outside the range -20°F to 200°F.
FIX: Replace black Indoor Ambient Thermistor.

CODE: F4.
PROBLEM: Indoor Coil Thermistor either above or below operating tolerances.
FIX: Replace Red Indoor Coil Thermistor.

CODE: F5.
PROBLEM: Wireless Thermostat failure.
FIX: Attempt to rebind Wireless Thermostat or Replace Wireless Thermostat.

CODE: F6.
PROBLEM: Indoor Discharge Thermistor either above or below operating tolerances.
FIX: Replace Yellow Indoor Discharge Thermistor.

CODE: Fb.
PROBLEM: Low Remote Battery Warning.
FIX: Replace Batteries in Wireless Devices.

CODE: H1.
PROBLEM: High Voltage Protection engaged. Power supply voltage is to high.
FIX: Check for incoming power at correct voltage.

CODE: br.
PROBLEM: Brown Out Protection engaged. Power was lost or voltage is low.
FIX: Check for incoming power at correct voltage.

CODE: L6.
PROBLEM: Discharge Air Too Hot.
FIX: Clean Filter or Remove Air Blockage.

CODE: LC.
PROBLEM: Outdoor Coil Thermistor temperature high.
FIX: Clean Condenser Coils, Check Fan for fault. Code will reset after cleaning.

CODE: C2.
PROBLEM: Indoor Air Recirculation. Large delta between thermostat and return.
FIX: Clean Filter or Remove Air Blockage or Close Vent Door or Improve indoor to outdoor seal.

CODE: C5.
PROBLEM: Outdoor Coil temperature too high for outdoor ambient temperature.
FIX: Check for Blocked Outdoor Air or Clean Coil.

CODE: C1.
PROBLEM: Indoor Coil is freezing up.
FIX: Clean filter, Check for fan and blower operation, Check for Refrigerant loss or Restricted capillary tube.

CODE: C3.
PROBLEM: Indoor Coil is freezing up.
FIX: Clean filter, Check for fan and blower operation, Check for Refrigerant loss or Restricted capillary tube.

CODE: C4.
PROBLEM: Indoor Coil froze up.
FIX: Clean filter, Check for fan and blower operation, Check for Refrigerant loss or Restricted capillary tube.

CODE: C6.
PROBLEM: Poor Unit Performance.
FIX: Check for blower motor, compressor, or electric heat operation.

CODE: C7.
PROBLEM: Indoor Freezing Lockout (ICT – IAT > 20) +10 Min.
FIX: Clean filter, Check for fan and blower operation, Check for Refrigerant loss or Restricted capillary tube.

amana air conditioner codes

 


What Our Clients Are Saying About Us

They were professional and made excellent recommendations

Bob W.Courtice, ON

They were very professional and cleaned up any mess that was created

j-a-weeksOshawa, ON

The guys were all really nice and easy to deal with. Look forward to using them on my next project.

AllanWhitby, ON

The job went very smoothly and there was no mess left when they left.

SteveWhitby, ON

Daniel and his team are always very professional.

luciaOshawa, ON

They got everything done in one day, They made sure to explain what’s going on, so we didnt have to worry.

cjbaui_03Courtice, ON

Provided prompt reliable service and staff were knowledgeable and quite personable.

Joanna R.Whitby, ON

Dan and his staff that I have met are of the utmost professionals.

TigstrikerNewcastle, ON

Dan himself is an absolute pleasure with which to deal. He's friendly, honest, and never tries to upsell you.

JoeToronto, ON

We'll be adding them to our speed dial for our next heating and cooling jobs.

Steve in WhitbyWhitby, ON